Bentley WaterGEMS CONNECT Edition Help

Pressure Constraints Tab

Use this tab to define pressure constraints for all junctions or a set of junctions.

New Click to add a new design event. Opens the Select Snapshot box where you can select a new design event or an existing design event.

Click OK after you make a selection.

Duplicate Click to create a copy of the selected design event. This can be an efficient way to create a new design event that has many of the attributes of an existing event.
Delete Click to delete the selected design event.
Initialize Table from Selection Set Click to open the Initialize Table from Selection Set box where you can choose the Selection Set and the Design Event.

Click OK to run.

Design Event The name of the event.
Node Click the ellipsis to select the node from the drawing.
Min. Pressure Set a minimum pressure that you require for the selected set of junctions. Violations of this boundary are displayed when you calculate your network.
Max. Pressure Set a maximum pressure that you require for the selected set of junctions. This value cannot be lower than the minimum pressure you set. You can set this to an unusually high value if you are unconcerned with maximum pressure. Violations of this boundary are displayed when you calculate your network.
Consider Pressure Benefit? Select this check box if you want the genetic algorithm to consider the benefits provided to your design by higher system pressures.